[Picture1]

Spectral Sensitivity Characteristics of ICX098 CCD chip used in the Philips ToUcam.

As can be seen the spectral response of this CCD when used for producing RGB images from splitting from the master colour image will not produce data of the same quality as of the images had been obtained through the proper filters.

The problem lies in that, the response of the chip in Blue and green overlap a great deal at ~475nm. Also, a R leak occurs going far back into the 450nm range. Note that simply using an IR block filter will only help a little to cut the R end of the response down, but the problem still lies in G-B overlap, and the red leak.

This in summary means that the Blue image data is “polluted” with G and R (which is why the surface features remain visible, even when an IR block filter is used.) Also, the G image data is slightly polluted by the Red leak.

In further reviewing the documentation, the way in which the CCD reads the data out also causes problems, as 2 x as much G signal is generated than R or B.

We present one possible solution to this problem below.

[Picture2]

Spectral Sensitivity Characteristics of True Technology CMY filters

Looking at the spectral characteristics of the TT CMY filters, we can “pre-filter” the ICX098 CCD chip with the magenta filter including a suitable IR rejection filter. This will get rid of the band from 500nm to 600nm, and block both the G leak into Blue, and Red leak. Signal lost in R and B would be kept to a minimum.

We can reconstruct a synthetic G from the R and B (with a ratio that can be easily worked out). Since the G frame normally does not contain useful data for Mars, this will help to get better B and R frames using the ToUcam with very minimum modification and hopefully will encourage more submitted images with useful data.

Our final thoughts however, are perhaps while the ToUcam is a superb choice for producing high resolution colour imagery, perhaps the cooled CCD systems with proper filters still very much have the edge when one wishes to produce filtered imagery of Mars.

Best Regards,

Damian Peach
Tan Wei Leong.

ALPO-JAPAN 메일링 그룹에 현재 많은 좋은 사진들을 올리고 있는 영국의 Mr.Damian과 싱카포르의 Mr,Tan Wei Leong씨가 보내온 자료입니다.
ToUcam 사용하시는 분들은 참조하세요...

천체사진 카메라

천체사진 카메라의 모든정보(사용기,신제품정보,개조 등)

List of Articles
번호 분류 제목 글쓴이 날짜 조회 수
254 디지탈카메라 필터제거 6D 와 삼양 135mm 렌즈의 궁합은? file 박영식 2019.07.08 746
253 디지탈카메라 필터 제거 6D + Astronomik Ha(12 nm) clip for FF 3 file 박영식 2018.08.06 813
252 디지탈카메라 X-E1 + 삼양 24mm(f/1.4) 2 file 박영식 2015.08.07 1015
251 디지탈카메라 X-E1 + 펜탁스 SMC 50mm(f/1.4) file 박영식 2015.08.07 1045
250 디지탈카메라 Fujifilm X-E1 2nd file 박영식 2015.01.16 1068
249 디지탈카메라 Fujifilm X-E1 9 file 박영식 2015.01.16 1185
248 냉각CCD QHY16200A의 dark frame file 이건호 2016.03.24 1203
247 디지탈카메라 냉각 6d + 탐론 15-30 file 이건호 2015.08.07 1329
246 디지탈카메라 Fujifilm X-E1 dark 7 file 박영식 2015.01.21 1366
245 디지탈카메라 5D mk3 vs X-E1 9 file 박영식 2015.01.20 1582
244 냉각CCD ZWO ASI2600MC Pro 사용기 (냉각 CMOS) 1 file 이준화 2020.04.10 1751
243 디지탈카메라 냉각 6D + 삼양 135mm 원본 file 이건호 2015.09.23 1944
242 SDT80 + 냉각6D 1장 원본 1 file 이건호 2017.01.31 2464
241 냉각CCD 냉각6D + 시그마 아트50미리 풀프레임 7 file 이건호 2016.06.30 2975
240 디지탈카메라 Sony A7s 6 박영식 2014.08.05 3269
239 냉각CCD 이미징 리소스사 dmk카메라 리뷰 자료 file 김종호 2013.07.24 3792
238 기타 ICX445AL 센서 양자효율 비교 자료 2 file 이건호 2014.05.13 4288
237 냉각CCD CDS-1100 리뷰 file starlit 2012.05.23 5137
236 냉각CCD [re] BJ-42 : Matsumoto 4 박성래 2003.05.26 5509
235 디지탈카메라 E-300 흑백 센서 개조 file 이준화 2012.01.18 5547
Board Pagination Prev 1 2 3 4 5 6 7 8 9 10 ... 13 Next
/ 13

NADA. Network of Amatuer Digital Astrography © Since 2003, All Rights Reserved

Design ver 2.0 / Google Chrome 에 최적화 되어 있습니다.

sketchbook5, 스케치북5

sketchbook5, 스케치북5

나눔글꼴 설치 안내


이 PC에는 나눔글꼴이 설치되어 있지 않습니다.

이 사이트를 나눔글꼴로 보기 위해서는
나눔글꼴을 설치해야 합니다.

설치 취소