Skip to content

?

단축키

Prev이전 문서

Next다음 문서

크게 작게 위로 아래로 댓글로 가기 인쇄 첨부
?

단축키

Prev이전 문서

Next다음 문서

크게 작게 위로 아래로 댓글로 가기 인쇄 첨부




[Picture1]

Spectral Sensitivity Characteristics of ICX098 CCD chip used in the Philips ToUcam.

As can be seen the spectral response of this CCD when used for producing RGB images from splitting from the master colour image will not produce data of the same quality as of the images had been obtained through the proper filters.

The problem lies in that, the response of the chip in Blue and green overlap a great deal at ~475nm. Also, a R leak occurs going far back into the 450nm range. Note that simply using an IR block filter will only help a little to cut the R end of the response down, but the problem still lies in G-B overlap, and the red leak.

This in summary means that the Blue image data is “polluted” with G and R (which is why the surface features remain visible, even when an IR block filter is used.) Also, the G image data is slightly polluted by the Red leak.

In further reviewing the documentation, the way in which the CCD reads the data out also causes problems, as 2 x as much G signal is generated than R or B.

We present one possible solution to this problem below.

[Picture2]

Spectral Sensitivity Characteristics of True Technology CMY filters

Looking at the spectral characteristics of the TT CMY filters, we can “pre-filter” the ICX098 CCD chip with the magenta filter including a suitable IR rejection filter. This will get rid of the band from 500nm to 600nm, and block both the G leak into Blue, and Red leak. Signal lost in R and B would be kept to a minimum.

We can reconstruct a synthetic G from the R and B (with a ratio that can be easily worked out). Since the G frame normally does not contain useful data for Mars, this will help to get better B and R frames using the ToUcam with very minimum modification and hopefully will encourage more submitted images with useful data.

Our final thoughts however, are perhaps while the ToUcam is a superb choice for producing high resolution colour imagery, perhaps the cooled CCD systems with proper filters still very much have the edge when one wishes to produce filtered imagery of Mars.

Best Regards,

Damian Peach
Tan Wei Leong.

ALPO-JAPAN 메일링 그룹에 현재 많은 좋은 사진들을 올리고 있는 영국의 Mr.Damian과 싱카포르의 Mr,Tan Wei Leong씨가 보내온 자료입니다.
ToUcam 사용하시는 분들은 참조하세요...

천체사진 카메라

천체사진 카메라의 모든정보(사용기,신제품정보,개조 등)

List of Articles
번호 분류 제목 글쓴이 날짜 조회 수
134 냉각CCD 냉각 CCD 입문 3 file 박병우 2003.05.16 7179
133 냉각CCD Image Reduction (또는 Image Calibration) 4 file 이건호 2003.05.19 7185
132 디지탈카메라 니콘 신제품 DSLR D70 2 지승용 2004.02.04 7191
131 냉각CCD 냉각 CCD 입문 4 file 박병우 2003.05.16 7207
130 기타 ToUcam pro 이상있을때... file 이건호 2003.07.29 7219
129 냉각CCD 냉각 CCD 입문 2 1 file 박병우 2003.05.16 7231
128 냉각CCD 냉각 CCD 입문 6(냉각 방법, 이슬 대책) file 박병우 2003.05.27 7275
127 기타 VCAM 개조 1 file 이준화 2003.07.14 7277
126 냉각CCD CCD 영상처리 예제 file 이준화 2003.04.08 7286
125 기타 [re] ToUcam 필터개조 2/2 file 이건호 2003.07.21 7296
124 디지탈카메라 300D + 셀레스트론 UHC필터(바더 OEM 제품) 4 file 박대영 2005.10.11 7310
123 디지탈카메라 D70 적녹현상 3 박현권 2004.03.22 7314
122 냉각CCD 냉각 CCD 입문 5(냉각 CCD, A/D 변환방법) file 박병우 2003.05.27 7317
121 기타 VCAM 개조 2탄 8 file 이준화 2003.07.16 7328
120 기타 [re] PC 카메라로 자동가이드할때 사용되는 회로 1 file 박현권 2004.09.30 7332
119 디지탈카메라 D3 Noise test도 올려봅니다. 3 file 신병석 2009.01.09 7335
118 디지탈카메라 [re] 5D Mark II 실사이즈 처리안한 원본 1 file 황인준 2009.01.09 7373
117 기타 [re] PC 카메라로 자동가이드할때 사용되는 회로 3 file 이건호 2003.07.25 7385
116 디지탈카메라 CP4500 -White Balance 재 설정과 현실감 있는 색의 재현 file 황인준 2003.04.11 7402
115 냉각CCD MaxImDL 이건호 2004.10.19 7461
Board Pagination Prev 1 2 3 4 5 6 7 8 9 10 11 ... 13 Next
/ 13

NADA. Network of Amatuer Digital Astrography © Since 2003, All Rights Reserved

Design ver 2.0 / Google Chrome 에 최적화 되어 있습니다.

sketchbook5, 스케치북5

sketchbook5, 스케치북5

나눔글꼴 설치 안내


이 PC에는 나눔글꼴이 설치되어 있지 않습니다.

이 사이트를 나눔글꼴로 보기 위해서는
나눔글꼴을 설치해야 합니다.

설치 취소